National Honey Board European Union Export Program Instructions

Testing and Sampling Requirements and Procedures

Under the proposal accepted by the European Union, handlers must follow a certain testing and sampling protocol with respect to the frequency of testing and the compounds that must be monitored. Each sample drawn must be tested for the compounds listed below at one of the two certified labs.

Sampling Frequency

Raw Product/Bulk:
One sample* drawn from each 10 drums including
at least one sample from each producer represented in the load

Finished Goods:
One sample* per container load of finished goods including, at minimum, at least one
sample from each producer or variety represented in the container load.

*Sample size: 250 grams or as specified by test laboratory used

 

Compound Testing Requirements*

Compound

Tolerance

Antibiotics:

Sulfonamides

None

Tetracyclines

None

Streptomycine

None

Chloramphenicol

None

Nitrofurans

None

Tylosin

None

Acaricides:

Coumaphos

100ppb

Amitraz

1000ppb

Fluvalinate

50ppb

Trade analysis:

HMF

All Per Codex

Moisture

Stan 12-1981,

Diastase

Rev.1 (1987),

Ph

Rev.2 (2001)

Acidity

 


*Individual customers may require further testing

Two laboratories are authorized by the E.U. for product testing under the program; Applica GmbH or Quality Services International GmbH as summarized in the linked pages on this site. Test results and documentation must be included with shipping documents for each shipment.

Sample discounted pricing, as submitted by each lab, for the complete required testing series is documented on this site. However, please contact each lab to obtain your own quote. Pricing is subject to change and exporters must contract individually with the laboratory of their choice.

Back to Program Instructions